Building Permit Details
Permit Number:
24-10372
Permit Status:
Completed
Permit Type:
Building
Project Type:
Residential
Description of Work:
RS - Residential
Scope of Work:
Alteration
Issued Date:
07/02/2024
CO Issue Date:
Plans Examiner:
Christopher Polanski
Job Address:
10245 BANEBERRY PL HIGHLANDS RANCH, CO 80129
Building Code:
2021 IRC
Inspections
Contractors
Permit Fees
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Drywall
07/29/2024
Disapproved
Dusty Welz
1. Two shower walls approved only. Okay to water proof those showers but full house still needs drywall inspection.
2. Also test and inspection required for shower pan.
Print Report
Drywall
08/01/2024
Approved
Robert Stratton
Print Report
Electric Service Equipment
07/23/2024
Disapproved
Richard Perrone
1. Tighten loose riser.
2. Label all circuits - 408.4.
3. Supplemental ground rod required - 250.53(A)(2).
4. #4 Cu GEC to water pipe continuous - 250.64(C). Appears that only a jumper is installed around meter. Cannot reach bottom clamp to verify. Termination shall remain accessible - 250.68(A).
Print Report
Electric Service Equipment
01/14/2025
Disapproved
Matt Mazzara
1)cold water pipe GEC must terminate within first 5’ of entry
Print Report
Electric Service Equipment
01/29/2025
Approved
Matt Mazzara
Xcel 01/30/2025
Print Report
Final Building
01/14/2025
Approved
Anthony Frank
Water temperatures to be adjusted by end of business today, walked with the builder. Freestanding tub to be adjusted at the 1070.
Water in the main house is 135 degrees. Adjust accordingly. Find a building approved pending final electric approval.
Print Report
Final Electric
01/14/2025
Disapproved
Matt Mazzara
1)right mst bath recep inoperable
2)breaker lock req at hood per 110.25
Print Report
Final Electric
01/29/2025
Approved
Matt Mazzara
Print Report
Final Energy Compliance
01/14/2025
Approved
Anthony Frank
This is a remodel job, existing HVAC
Print Report
Insulation Thermal
07/24/2024
Approved
Dusty Welz
Insulation approved but you need to get your rough electrical approved prior to next building inspection
Print Report
Interior Gas Line
07/23/2024
Approved
Anthony Frank
No new gas lines installed, replaced gas fireplace, BTUs are within industry standards.
Print Report
Rough Electric
07/23/2024
Disapproved
Richard Perrone
1. Max 4 cables in stack-it’s for more than 24” (bundling). Derate conductor per 310.15(C) or provide separation. Check throughout.
2. Dining room receptacles shall be on a 20A circuit - 210.11(C)(1), 210.52(B).
3. Nail plates where marked.
Notes: Per DC amendments max 10 openings on 15A ckts, 12 openings on 20A ckts and 4 openings on small appliance branch circuits. Provide written breakdown of new and existing/modified circuits.
Print Report
Rough Electric
07/25/2024
Approved
Richard Perrone
Print Report
Rough Energy Compliance
07/23/2024
Disapproved
Anthony Frank
Window inspection can be completed at the rough energy compliance reinspection. Address all tempered glass requirements.
Print Report
Rough Energy Compliance
08/20/2024
Approved
Dusty Welz
Approved
Print Report
Rough Frame
07/23/2024
Approved
Anthony Frank
Windows have not been replaced at this point, I walked with the builder in reference to tempered glass windows to be addressed.
Print Report
Rough HVAC
07/23/2024
Approved
Anthony Frank
Cooktop exhaust has been verified at 600 CFM, make up air has been provided.
Print Report
Rough Plumbing
07/23/2024
Approved
Anthony Frank
Must provide a 1070 mixing valve for the freestanding tub. Install notch plate on the shower valve.
Print Report
Shower Pan
08/01/2024
Approved
Robert Stratton
Print Report