Building Permit Details
Permit Number: 22-11317
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Custom
Scope of Work: New
Issued Date: 10/27/2022
CO Issue Date: 02/28/2024
Plans Examiner: Anthony Petty, Stuart Foster
Job Address: 2852 MYSTIC DOE CT FRANKTOWN, CO 80116
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 06/12/2023
Steel Letter 06/12/2023
Survey 06/12/2023
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Construction Meter 12/02/2022 Disapproved Justin Lett 2020 NEC—1. EGC and neutral in feeder conduit required to be per 250.119 and 200.6 2. Feeder conduit EGC required to be sized to upstream OCPD 3. Retained Main required at temp with retainer and barriers 4. 240V recep requires GFCI protection 5. Replace damaged liquidtight  
Construction Meter 12/07/2022 Approved Justin Lett CORE 12/08/2022
Driveway Preliminary 10/03/2022 Approved June Amicucci COMPLY WITH Douglas County Standards DOUGLAS.co.us/documents/driveway-regulations
Driveway must have turn around at house see regs
Drywall 07/10/2023 Approved Rick Chadwick  
Electric Service Equipment 08/28/2023 Disapproved Justin Lett 1. Ped risers to extend 18” below grade 2. Ped terminations incomplete 3. Identify feeder neutral at all terminations per 200.6

Note-UFER in garage left of sub panels
 
Electric Service Equipment 10/13/2023 Approved Justin Lett CORE 10/16/2023
Electric Trench 12/02/2022 Approved Justin Lett Note-4/0urd w/#2 EGC ped to house  
Electric Trench 06/14/2023 Approved Justin Lett Note-trench run relocated. Now runs from ped to garage. 2 x 4/0urd w/#2 EGC  
Exterior Wall Sheathing 03/20/2023 Approved Rick Chadwick  
Final Building 11/15/2023 Disapproved Rick Chadwick 1. Complete chimney cap 2. Paint exterior PVC 3. Back draft damper at middle of the three stuck shut 4. Splash blocks at sill cocks 5. Seal exposed osb at deck and close open area 6. Seal gasline penetration at deck rim 7. Enclose opening above front entry 8. Fire caulk penetrations at garage wall 9. Strap dishwasher discharge and provide air gap 10. Secure guard rail at deck 200 lb lateral load check all 11. Complete column caps 12. Post correct address  
Final Building 11/16/2023 Approved Rick Chadwick  
Final Defensible Space 10/23/2023 Approved Jill Welle Clean up oak clump and dead material
Final Driveway 10/23/2023 Disapproved June Amicucci Driveway need turnaround at house per COMPLY WITH Douglas County Standards., LEFT MESSAGE for builder to call.
Final Driveway 10/31/2023 Approved June Amicucci No issues found for the final driveway inspection
Final Electric 11/08/2023 Disapproved Justin Lett 1. Box and fixture at front porch requires minimum damp rating 2. Seal tops and sides of exterior fixtures to prevent water intrusion 3. Terminate conductors in A/C disconnect 4. Wall oven not set/wired 5. Inadequate number of receps to cover island square footage-main kitchen 6. Upper deck lights inoperable-no lamps present 7. M bath shower lights incomplete 8. Unfinished space bottom of stairs requires GFCI protected receptacle 9. Exhaust fan motors missing in multiple bathrooms 10. Unable to inspect well disc-taped closed 11. Cover horizontal NM cables in unfinished walls 12. Inadequate receptacle coverage lower kitchen island 13. Plate missing lower kitchen island 14. Smoke/CO required outside lower master suite-maintain required distance from range. Current alarm is greater than 15’ from bedroom entrance 15. Label and lockout both hood breakers 16. A/C not set/wired 17. Floors completely covered-unable to verify/test any floor receps, if present  
Final Electric 11/14/2023 Approved Justin Lett
Note-A/C not being installed with build. Separate permit required when installed
 
Final Energy Compliance 11/15/2023 Approved Rick Chadwick  
Final HVAC 11/15/2023 Approved Rick Chadwick See Final Building  
Final Plumbing 11/15/2023 Approved Rick Chadwick See Final Building  
Foundation Insulation 11/15/2022 Approved Rick Chadwick  
Insulation Thermal 06/27/2023 Approved Fredrick Mooney  
Insulation Thermal 06/28/2023 Cancelled Fredrick Mooney Duplicate  
Interior Gas Line 06/20/2023 Disapproved Rick Chadwick 10 lb test on 30 lb gauge  
Interior Gas Line 06/22/2023 Approved Rick Chadwick Black Hills Energy 06/22/2023
Moisture Barrier 05/15/2023 Cancelled Bryce Ryberg GC canceled due to weather  
Moisture Barrier 08/10/2023 Approved Rick Chadwick Change to Moisture Barrier and approve  
Preliminary Defensible Space 10/05/2022 Approved Jill Welle
Final inspection required
Roof Truss 03/20/2023 Disapproved Rick Chadwick 1. FJ1 and FJ2 need to provide bearing and truss clips 2. Truss clips at garage bearing wall E3 and E4
trusses
 
Roof Truss 05/02/2023 Approved Rick Chadwick Apply plywood gussets at trusses wiil check at Rough Frame  
Rough Electric 06/14/2023 Disapproved Justin Lett 1. NPs at SER in garage at top plates, laundry, guest bath, rec room, bsmt bath, bsmt bed, j and j bath, SE bedroom, small closet by lower FP-check all 2. Vehicle bay recep circuit cannot feed opener receps 3. Recep requires within each vehicle bay 4. Counter top recep spacing left of sink near pass through 5. Complete all exterior boxes 6. Fan rated box at nook-314.27 7. Fill open KO m bath pan box 8. 1-1/4” rule at staples at landing and throughout-300.4 9. Bond metal boxes in mech room 10. NM not permitted in raceway underground 11. Submit revisions for second kitchen at lower level 12. Max 4 receps per kitchen circuit. Unsure how the 3 receps at island are being fed 13. Make up and bond all boxes inside and outside  
Rough Electric 06/16/2023 Disapproved Justin Lett Corrections incomplete from previous—-6. Fan rated box at nook-314.27 11. Submit revisions for second kitchen at lower level  
Rough Electric 06/20/2023 Disapproved Justin Lett Corrections incomplete from previous—-6. Fan rated box at nook-314.27  
Rough Electric 06/21/2023 Approved Justin Lett  
Rough Energy Compliance 06/22/2023 Approved Rick Chadwick  
Rough Frame 06/20/2023 Disapproved Rick Chadwick 1. Call Rough Energy Compliance 2. DWV not on test at laundry 3. Check all header sizes see dining room. TERMINATE INSPECTION  
Rough Frame 06/22/2023 Disapproved Rick Chadwick 1. DWV lost test upper level laundry 2. Nail plates basement laundry and kitchen 3. Backfill or level master lav 4. Stud shoes at overbores OK TO INSULATE PER ELECTRICAL  
Rough Frame 06/27/2023 Approved Fredrick Mooney  
Shower Pan 10/04/2023 Approved Fredrick Mooney  
Ufer Ground Electrode 06/12/2023 Approved Wayne Elmore Eng Letter  
Underground Plumbing 01/18/2023 Disapproved Clayton Rodeback Pipes are covered in snow.  
Underground Plumbing 01/23/2023 Approved Rick Chadwick  
Weather Resistive Barrier 05/02/2023 Disapproved Rick Chadwick 1. Install all quick flashing correctly 2. Seal all penetrations 3. Install counter flashing at deck 4. Close openings with osb and tape joints at missing windows 5. Flashing at front entry  
Weather Resistive Barrier 05/17/2023 Disapproved Rick Chadwick Change to Weather Resistive Barrier and disapprove waiting on windows, complete counter flashing OK TO START SIDING