Building Permit Details
Permit Number: 21-08959
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Basement
Scope of Work: Alteration
Issued Date: 08/27/2021
CO Issue Date:
Plans Examiner: Stuart Foster
Job Address: 5394 SEDONA DR PARKER, CO 80134
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 11/01/2021 Approved Rick Chadwick  
Electric Service Equipment 01/26/2022 Disapproved Thomas Buzo Courtesy walk Only. No Inspection.

Note to Homeowner: No record of permit for kitchen remodel. Permit needed for kitchen remodel. New circuits have been added to kitchen that will need to be inspected. Please call with any questions.

Note: Original plans for a 400A service upgrade has been cancelled by the homeowner.(May upgrade in the future) Existing service to remain a 200A. Existing hot tub circuit will be disconnected at hot tub and panel to ensure Service load is below 200A. New branch circuits (Pre wire at this time ) such as new laundry, car charger will remain at locations and will be disconnected at panels and, at outlet boxes will be blanked off. A permit will be require for future 400A service upgrade and for pre wire branch circuits connections.
 
Electric Service Equipment 02/10/2022 Disapproved Thomas Buzo Amended
See Final Electric Inspection.
 
Final Building 02/09/2022 Disapproved Anthony Frank 1) The bedroom is lacking egress compliant ladder attached to the window well.
2) Install the trim cover for the refrigerator box.
3) Install the dishwasher and complete the indirect discharge.
 
Final Building 02/25/2022 Approved Clayton Rodeback  
Final Electric 02/10/2022 Disapproved Thomas Buzo 1) Sub Feeder strands shall not be damage at new basement sub panel terminals. 110.14
2)EGC's shall provide a thoroughly good connection, currently loose on left side of panel. 110.14
3)Terminate all EGC's at New basement sub panel.
4)cap off unused conductors inside sub panels.
5)Secure NM & SER cable within 12" Subpanel Enclosures. (Top and bottom)
6)Install the correct size NM cable connector for New sub panel feeder terminating into existing basement panel.
7)Protect horizontal runs of NM cable in unfinished area of basement.
8)No power to fridge and microwave.
9)GFCI protection req for receptacles within 6' of wet bar sink.
10)GFCI protection req for receptacles under wet bar sink.
11)Open Jboxes in crawl space.
12)Support SER in crawl space and terminate unused ends into boxes, (Can not leave ends hanging in crawl spaces)
13)Light missing in front of water heaters.
14)GFCI receptacles not allowed in ceiling. GFCI receptacles shall be readily accessible.
15)AFCI protection require for receptacles at bottom of stairs. 210.12
16)Hot tub loads puts service over 200A. Per Conversation with EC and GC, Hot tub was gonna be disconnected.

Note: Check exterior service equipment to ensure nothing changed.

 
Final Electric 02/24/2022 Disapproved Thomas Buzo 7) Protect horizontal runs of NM cable in unfinished area of basement.9)GFCI protection req for receptacles within 6' of wet bar sink. 12) terminate unused ends of service into boxes, (Can not leave ends hanging in crawl spaces)110.14 15)AFCI protection require for receptacles at bottom of stairs. 210.12

Note: Hot tub disconnected at time of inspection.

Service remained unchanged.
 
Final Electric 03/03/2022 Approved Thomas Buzo  
Fireblocking 10/21/2021 Approved Rick Chadwick  
Interior Gas Line 10/21/2021 Approved Rick Chadwick N/A  
Rough Electric 10/21/2021 Approved Henry VanSchaack **service upgrade later **  
Rough Frame 10/21/2021 Disapproved Rick Chadwick 1. Minimum stand pipe at auto wash 18” 2. Seal all plate penetrations at sub floor  
Rough Frame 10/25/2021 Approved Rick Chadwick