Building Permit Details
Permit Number: 21-06545
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Custom
Scope of Work: New
Issued Date: 03/01/2022
CO Issue Date: 08/15/2023
Plans Examiner: Anthony Petty
Job Address: 253 STONE POINTE TRL CASTLE ROCK, CO 80109
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 04/07/2022
Steel Letter 04/07/2022
Survey 07/21/2023
Survey 07/26/2023
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drip Edge 02/14/2023 Cancelled Clayton Rodeback Reschedule with other inspection. I can look at drip edge with mid roof inspection.  
Drip Edge 05/02/2023 Approved Clayton Rodeback  
Driveway Preliminary 07/16/2021 Approved Jill Welle
Drywall 03/21/2023 Disapproved Clayton Rodeback Partial For garage only  
Drywall 03/27/2023 Disapproved Clayton Rodeback Garage only. Rest of house not ready  
Drywall 03/29/2023 Disapproved Matt Dziubanski 1. Basement drywall needs to be cut up for the 3” float.
Ok to tape and mud.
 
Drywall 05/02/2023 Approved Clayton Rodeback  
Electric Service Equipment 03/03/2023 Cancelled Jeremy Bock Cancelled-not ready  
Electric Service Equipment 03/06/2023 Cancelled Jeremy Bock Cancelled-not ready  
Electric Service Equipment 03/08/2023 Approved Richard Perrone Core to install dual breaker kit at pedestal at future date CORE 03/08/2023
Electric Trench 09/01/2022 Approved Rick Sugar 1) Trench is approximately 130’, from the Core pedestal to the E side of the house, (2) runs of 4/0 and (2) #2 EGCs  
Electric Trench 07/27/2023 Approved Jeremy Bock 2 x 12/2 UF cable from garage to entry vestibule-one switch, one outlet  
Exterior Lath 03/29/2023 Approved Matt Dziubanski Front and back columns are not complete do to the concrete not poured and modifications. Will check at the next inspection.  
Exterior Underground Gas Line 09/12/2022 Approved Nick Martinell  
Exterior Wall Sheathing 10/31/2022 Disapproved Clayton Rodeback OK to wrap everything but stair tower.  
Exterior Wall Sheathing 11/04/2022 Approved Clayton Rodeback  
Final Building 08/01/2023 Disapproved Clayton Rodeback Complete all handrails/guard rails at exterior as needed.
Handrail required at garage stairs.
3. Activate self closing hinges at garage door.
4. Complete back patio pavers.
5.Install Guard rail at Juliet door front bedroom.
6. complete condensate drain from upstairs air handler.
7. Install blanket insulation at crawl space walls.
8.Unused 3” PVC pipe above tankless water heater.
9 Need to install code compliant stairs and handrail at front entry.
10.Paint exterior gas Service line.
Recall with final energy compliance
 
Final Building 08/14/2023 Approved Clayton Rodeback  
Final Defensible Space 07/31/2023 Disapproved Jill Welle Thin oak clump in back corner to remove dead, remove small stems to achieve a 3 ft to 5 ft stem spacing and prune to remove contact with surface fuels. End on slope drop off.
Final Defensible Space 08/01/2023 Approved Jill Welle
Final Driveway 07/31/2023 Approved June Amicucci No issues found for final driveway inspection
Final Electric 07/27/2023 Approved Jeremy Bock  
Final Energy Compliance 08/15/2023 Approved Clayton Rodeback  
Fireblocking 01/05/2023 Approved Clayton Rodeback  
Foundation Insulation 04/08/2022 Approved Kerry Keller  
Insulation Thermal 03/14/2023 Disapproved Clayton Rodeback Complete air barriers at stair walls and vault ceilings.  
Insulation Thermal 03/15/2023 Approved Clayton Rodeback  
Interior Gas Line 01/06/2023 Approved Clayton Rodeback  
Midroof 05/02/2023 Approved Clayton Rodeback  
Moisture Barrier 03/29/2023 Approved Matt Dziubanski  
Preliminary Defensible Space 07/16/2021 Approved Jill Welle Final inspection required
Roof Truss 01/05/2023 Disapproved Clayton Rodeback C4 broken TC at garage back wall above windows.
D2 at kitchen require engineer truss repair x2.
provide truss repair from Engineer.
Install uplift hardware At girders.
 
Roof Truss 03/06/2023 Approved Clayton Rodeback GC called to move inspection to 3/6  
Rough Electric 03/03/2023 Disapproved Jeremy Bock 1. NP-garage east wall
2. Secure 14/2 at can light-laundry room-south can
3. Add outlet-dining room at window wall
4. Master bedroom fireplace wiring incomplete
5. Outlets required within 6 ft of both master bedroom exterior doors
6. Fan wiring incomplete at master bedroom closet/ laundry
7. Outlet at doorway in master closet/ laundry required on 29A circuit
8. Move outlets to stud face in NE bedroom walls
9. Add outlet-right of doorway in NE bedroom
10. Additional support required at 14/2 cable above closet in NE bedroom
-inspection terminated at main level-2nd floor and basement not inspected
 
Rough Electric 03/06/2023 Disapproved Jeremy Bock 1. Master bedroom laundry outlet at doorway required to be on 20A circuit
2. Secure light box at stair landing-1st to second floor
3. Add outlet in dining area at window wall
4. Master bedroom laundry fan not wired
5. Bond basement stair light switch box-bottom of stairs
6. Move outlet box to front of studs-NW basement bedroom bathroom
7. NP-basement bar at window
8. Incomplete wiring at basement fireplace-12/2 cable coiled up at right side
9. Secure can lights in basement gym area
10. Outlet boxes missing at master bedroom-each side of doors
11. Outlet box missing at guest bedroom right of doorway
 
Rough Electric 03/08/2023 Approved Richard Perrone  
Rough Energy Compliance 03/06/2023 Approved Clayton Rodeback GC called to move inspection to 3/6  
Rough Frame 03/06/2023 Disapproved Clayton Rodeback 1.Fire block dead chases at kitchen and living room area.
2.Master bath group DWV loss test.
3.Nail plates at auto wash drain in master closet.
4.Air barrier at rake walls in guest suite.
5.Air barrier required at stair walls to attic space.
6.Hangers at basement stair landing.
7.Rough in water heater vents.
OK to insulate Pending rough electric
 
Rough Frame 03/15/2023 Approved Clayton Rodeback  
Shower Pan 05/04/2023 Approved Clayton Rodeback Looked at pans at drywall reinspect  
Underground Plumbing 07/22/2022 Approved Kerry Keller Please provide the county the gate code for next inspections or type it into your comment screen  
Weather Resistive Barrier 01/05/2023 Approved Clayton Rodeback Repair and tape missing tyvek at garage wall.
Tape all side wall penetrations.