Mechanical Permit Details
Permit Number: 25-00293
Permit Status: Issued
Permit Type: Mechanical
Type of Work: Furnace/AC Combo
Issued Date: 01/10/2025
Job Address: 2222 MOUNTAIN SAGE TER HIGHLANDS RANCH, CO 80126
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Air Conditioner 01/13/2025 Approved Matt Mazzara  
Final Electric 01/13/2025 Disapproved Matt Mazzara See HVAC  
Final HVAC 01/13/2025 Disapproved Matt Mazzara 1)furnace installed is direct vent only per manufacturer, non direct not permitted. Terminations must be performed manufacturer
2)CO dets req within 15’ outside all bedrooms
3)list electric contractor on permit for new electric installed
4)furnace vent terminations not permitted in electric service workspace 110.26
5)ground AC service recep box 250.148 and max #12 conductor at GFCI recep