Building Permit Details
Permit Number: 23-03374
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Residential
Scope of Work: Alteration
Issued Date: 05/01/2023
CO Issue Date:
Plans Examiner: Anthony Petty
Job Address: 400 N RUSSELLVILLE RD FRANKTOWN, CO 80116
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 09/05/2023 Approved Rick Chadwick Secure Den Shield and complete shower pan inspection  
Final Building 12/29/2023 Approved Clayton Rodeback  
Final Electric 12/14/2023 Cancelled Justin Lett GC cancelled  
Final Electric 12/29/2023 Disapproved Justin Lett 1. Dryer requires GFCI protection-210.8 2. Receptacle in lower m bedroom behind door requires TR type-406.12  
Final Electric 01/31/2024 Approved Justin Lett  
Insulation Thermal 07/03/2023 Disapproved Fredrick Mooney No answer at door.  
Insulation Thermal 08/21/2023 Approved Rick Chadwick  
Interior Gas Line 06/27/2023 Cancelled Fredrick Mooney N/A  
Interior Gas Line 08/21/2023 Approved Rick Chadwick  
Rough Electric 06/09/2023 Disapproved Justin Lett Smoke alarms required in each lower bedroom, main floor and upper loft. All require commercial power, battery backup, interconnected. Interconnection can be wireless-battery only not permitted



 
Rough Electric 06/12/2023 Approved Justin Lett  
Rough Frame 06/27/2023 Disapproved Fredrick Mooney Stud shoes still missing under kitchen sink.
Ok to insulate.
Recall rough with insulation.
 
Rough Frame 08/21/2023 Approved Rick Chadwick  
Rough HVAC 06/09/2023 Disapproved Rick Chadwick Run vents to exterior hydronic test ok  
Rough Plumbing 06/09/2023 Disapproved Rick Chadwick 1. Remove old condensate tea and install coupler.2. Foam all plate penetrations. Draftstop 3. Stud shoes at overbores and some support at 3” DWV  
Rough Plumbing 06/27/2023 Disapproved Fredrick Mooney See rough.  
Rough Plumbing 07/03/2023 Disapproved Fredrick Mooney No answer at door.  
Shower Pan 09/18/2023 Disapproved Rick Chadwick Change from Moisture Barrier to Shower Pan inspection and cannot verify code compliance tiles already installed contractor was told at Drywall inspection that we would look at fasteners at our Shower Pan inspection which was never called  
Shower Pan 09/22/2023 Approved Rick Chadwick  
Underground Plumbing 05/23/2023 Approved Rick Chadwick