Building Permit Details
Permit Number: 22-04680
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Residential
Scope of Work: Alteration
Issued Date: 06/15/2022
CO Issue Date:
Plans Examiner: Stuart Foster
Job Address: 2701 CASTLE PINES DR NORTH CASTLE ROCK, CO 80108
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 09/12/2022 Disapproved Nick Martinell Partial drywall inspection, kitchen, dining, laundry and powder bath on right side upper level okay. Need to inspect all other areas once completed  
Drywall 09/14/2022 Disapproved Nick Martinell Front study and main living okay, need to complete master bedroom and basement  
Drywall 09/15/2022 Approved Nick Martinell  
Electric Service Equipment 07/06/2023 Disapproved Jeremy Bock Line side terminations at exterior disconnects incomplete-not ready for service inspection  
Electric Service Equipment 07/12/2023 Approved Jeremy Bock CORE 07/13/2023
Electric Trench 06/16/2023 Approved Jeremy Bock Parallel 4/0, 2/0 neutral, #2 ground 75 ft from pedestal to house, 24”+ deep with warning ribbon  
Exterior Lath 08/29/2022 Approved Kerry Keller  
Final Building 07/28/2023 Disapproved Fredrick Mooney 1. Add water hammer arrestors at all dishwashers.
2. Handrails need to be graspable.
R311.7.8.5 section 2.
3. Pipe t&P valve to floor drain at mech room.
 
Final Building 11/29/2023 Approved Clayton Rodeback  
Final Electric 07/20/2023 Disapproved Jeremy Bock 1. 2 outlets missing at kitchen island
2. Grommet required at dishwasher cord cabinet penetration-check both
3. GFCI protection required at kitchen countertop outlet-right of window
4. Update panel labeling-all panels
-check arc fault protection at next inspection
 
Final Electric 07/26/2023 Approved Jeremy Bock  
Insulation Thermal 09/01/2022 Approved Kerry Keller  
Interior Gas Line 08/29/2022 Cancelled Kerry Keller N/A  
Interior Gas Line 08/31/2022 Cancelled Kerry Keller N/A  
Rough Electric 08/29/2022 Disapproved Rick Sugar 1) 13.5x7.5 6 outlets required at the kitchen island
2) No more than 4 openings on a small appliance circuit,
3) Provide lighting load calculation for all circuits exceeding 10 openings , throughout
4) 2’/ 4, rule at dining counter
5) #10 screws at dining fan box ,
6) 6’/12’ rule throughout study
7) 6’ rule left of the master bedroom door
8) Outlet left of the wet bar 2’ rule
9) 6’ rule L&R of the basement staircase
10 ) #10 screws at all fan boxes
 
Rough Electric 08/31/2022 Approved Rick Sugar  
Rough Frame 08/29/2022 Disapproved Kerry Keller Job site consultation walk-through with the builder and plumber
Rough Plumbing approved
Recall
 
Rough Frame 08/31/2022 Approved Kerry Keller