Permit Number:
22-04680
Permit Status:
Completed
Permit Type:
Building
Project Type:
Residential
Description of Work:
RS - Residential
Scope of Work:
Alteration
Issued Date:
06/15/2022
CO Issue Date:
Plans Examiner:
Stuart Foster
Job Address:
2701 CASTLE PINES DR NORTH CASTLE ROCK, CO 80108
Building Code:
2018 IRC
Inspections
Contractors
Permit Fees
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Drywall
09/12/2022
Disapproved
Nick Martinell
Partial drywall inspection, kitchen, dining, laundry and powder bath on right side upper level okay. Need to inspect all other areas once completed
Print Report
Drywall
09/14/2022
Disapproved
Nick Martinell
Front study and main living okay, need to complete master bedroom and basement
Print Report
Drywall
09/15/2022
Approved
Nick Martinell
Print Report
Electric Service Equipment
07/06/2023
Disapproved
Jeremy Bock
Line side terminations at exterior disconnects incomplete-not ready for service inspection
Print Report
Electric Service Equipment
07/12/2023
Approved
Jeremy Bock
CORE 07/13/2023
Print Report
Electric Trench
06/16/2023
Approved
Jeremy Bock
Parallel 4/0, 2/0 neutral, #2 ground 75 ft from pedestal to house, 24”+ deep with warning ribbon
Print Report
Exterior Lath
08/29/2022
Approved
Kerry Keller
Print Report
Final Building
07/28/2023
Disapproved
Fredrick Mooney
1. Add water hammer arrestors at all dishwashers.
2. Handrails need to be graspable.
R311.7.8.5 section 2.
3. Pipe t&P valve to floor drain at mech room.
Print Report
Final Building
11/29/2023
Approved
Clayton Rodeback
Print Report
Final Electric
07/20/2023
Disapproved
Jeremy Bock
1. 2 outlets missing at kitchen island
2. Grommet required at dishwasher cord cabinet penetration-check both
3. GFCI protection required at kitchen countertop outlet-right of window
4. Update panel labeling-all panels
-check arc fault protection at next inspection
Print Report
Final Electric
07/26/2023
Approved
Jeremy Bock
Print Report
Insulation Thermal
09/01/2022
Approved
Kerry Keller
Print Report
Interior Gas Line
08/29/2022
Cancelled
Kerry Keller
N/A
Print Report
Interior Gas Line
08/31/2022
Cancelled
Kerry Keller
N/A
Print Report
Rough Electric
08/29/2022
Disapproved
Rick Sugar
1) 13.5x7.5 6 outlets required at the kitchen island
2) No more than 4 openings on a small appliance circuit,
3) Provide lighting load calculation for all circuits exceeding 10 openings , throughout
4) 2’/ 4, rule at dining counter
5) #10 screws at dining fan box ,
6) 6’/12’ rule throughout study
7) 6’ rule left of the master bedroom door
8) Outlet left of the wet bar 2’ rule
9) 6’ rule L&R of the basement staircase
10 ) #10 screws at all fan boxes
Print Report
Rough Electric
08/31/2022
Approved
Rick Sugar
Print Report
Rough Frame
08/29/2022
Disapproved
Kerry Keller
Job site consultation walk-through with the builder and plumber
Rough Plumbing approved
Recall
Print Report
Rough Frame
08/31/2022
Approved
Kerry Keller
Print Report