Building Permit Details
Permit Number: 21-05289
Permit Status: Voided
Permit Type: Building
Project Type: Residential
Description of Work: RS - Basement
Scope of Work: Alteration
Issued Date: 06/09/2021
CO Issue Date:
Plans Examiner: Anthony Petty
Job Address: 9506 CHERRYVALE DR HIGHLANDS RANCH, CO 80126
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 08/02/2021 Approved Chris Fuller Basmt  
Final Building 01/14/2022 Approved Chris Fuller Smoke and CEOs tested and interconnected  
Final Electric 01/14/2022 Disapproved Damon Montroy 1. AFCI protection required for lights in basement family room.
2. Label new circuits in basement panel.
3. Kitchen island outlet exceeds the maximum of 6” under counter overhang.
4. Wire nuts not allowed for aluminum and copper connections at cook top. Use listed wire connectors.
5. Breaker locks required for double oven and cooktop.
6. GFCI protection required for dishwasher outlet.
7. Bathroom lights on with laundry circuit. GFCI protection required for laundry receptacle.
 
Insulation Thermal 07/27/2021 Approved Chris Fuller Fix small area of rim insulation by elec wires  
Interior Gas Line 07/21/2021 Approved Chris Fuller Fireplace holding at 10  
Rough Electric 07/21/2021 Disapproved Matt Mazzara 1)4 wire req to double oven
2)micro ded?
3)NP top plate above kitchen 3gang
4)secure LV to maintain 1” clearance to bsmt FP
5)NP by bsmt powder vanity
Note:per Doug Co amendments max 10 openings 15amp circuits, 12 openings 20amp circuits and 4 openings 20amp small appliance circuits that serve kit counter tops
 
Rough Electric 07/27/2021 Approved Matt Mazzara  
Rough Frame 07/21/2021 Approved Chris Fuller Move toilet flange min 15” from tub
Will check at insulation or drywall insp.
 
Underground Plumbing 06/11/2021 Approved Chris Fuller Basmt underground bath group