Building Permit Details
Permit Number: 15-10723
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Basement
Scope of Work: Alteration
Issued Date: 06/16/2015
CO Issue Date:
Plans Examiner: Anthony Petty, Daniel Davis, Dave Ransom, Donna Martin, Greg Lillmars, Leonard Lucero, Martha Mahr, Patricia Roach, Rana Rasteh, Rose Dederick, Wayne Elmore
Job Address: 3780 FAIRBROOK PT HIGHLANDS RANCH, CO 80130
Building Code: 2012 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 07/07/2015 Approved Courtney Arford  
Final Building 08/24/2015 Approved Courtney Arford  
Final Electric 08/24/2015 Disapproved Rick Sugar Guard strips req'd in the unfinished area and in the mech room
6'/12' rule in the bench area
and wetbar knee wall
Cannot run cooler SO cord through a wall
Rough insspection not approved
No more than 10 openings on a 15 amp circuit,,11 openings in the exercise room and 15 lights in the rec room
ARC fault throughout
as noted on 6/23
 
Final Electric 08/28/2015 Disapproved Rick Sugar No answer,no contractor  
Final Electric 08/31/2015 Approved Rick Sugar  
Insulation Thermal 06/26/2015 Approved Clayton Rodeback  
Interior Gas Line 06/23/2015 Approved Clayton Rodeback  
Rough Electric 06/23/2015 Disapproved David Lewis need receptacles 6ft-12ft spacing wall opposite bar  
Rough Frame 06/23/2015 Approved Clayton Rodeback