Building Permit Details
Permit Number: 12-15016
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Duplex
Scope of Work: New
Issued Date: 12/05/2012
CO Issue Date: 06/19/2013
Plans Examiner: Angie Velasquez, Daniel Davis, Dave Ransom, Leonard Lucero, Martha Mahr, Matt Archer, Rose Dederick
Job Address: 4334 CHATEAU RIDGE RD CASTLE ROCK, CO 80108
Building Code: 2006 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 03/21/2013
Steel Letter 03/21/2013
Survey 03/21/2013
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Construction Meter 12/18/2012 Approved Rich Edgett IREA 12/19/2012
Drip Edge 03/14/2013 Cancelled Kerry Keller  
Drip Edge 03/15/2013 Approved Kerry Keller  
Drywall 04/08/2013 Approved Kerry Keller  
Electric Service Equipment 03/28/2013 Approved Rich Edgett Meter is already set IREA 03/29/2013
Electric Trench 03/21/2013 Approved Rich Edgett Service Lateral  
Exterior Lath 04/12/2013 Disapproved Kerry Keller 1- your weep screeds has very little holes in screed and some has no holes. please provide manufacturer specs.  
Exterior Lath 04/15/2013 Approved Kerry Keller  
Exterior Lath Partial 04/29/2013 Cancelled Kerry Keller  
Exterior Wall Sheathing 02/20/2013 Approved Kerry Keller  
Final Building 06/17/2013 Disapproved Kerry Keller res  
Final Building 06/18/2013 Approved Kerry Keller  
Final Electric 06/17/2013 Disapproved Rich Edgett Scanned Ticket  
Final Electric 06/18/2013 Approved Rich Edgett Grommet hole to be installed @ desk (Granite is backordered)
Correct and Procede
 
Final Energy Compliance 06/17/2013 Disapproved Kerry Keller res  
Final Energy Compliance 06/18/2013 Approved Kerry Keller  
Final HVAC 06/04/2013 Disapproved Kerry Keller see insp in cms  
Final HVAC 06/17/2013 Approved Kerry Keller  
Final Plumbing 06/17/2013 Disapproved Kerry Keller res  
Final Plumbing 06/18/2013 Approved Kerry Keller  
Firewall 03/05/2013 Cancelled Kerry Keller  
Firewall 03/06/2013 Approved Kerry Keller  
Insulation Thermal 04/01/2013 Disapproved Kerry Keller Need your Rescheck for inspection  
Insulation Thermal 04/03/2013 Approved Kerry Keller  
Interior Gas Line 03/19/2013 Approved Kerry Keller Black Hills Energy 03/20/2013
Midroof 03/12/2013 Cancelled Kerry Keller Not Ready  
Midroof 03/20/2013 Approved Rich Garrett  
Moisture Barrier 03/05/2013 Cancelled Kerry Keller  
Moisture Barrier 04/29/2013 Approved Kerry Keller  
Roof Truss 03/05/2013 Cancelled Kerry Keller  
Roof Truss 03/06/2013 Approved Kerry Keller  
Rough Electric 03/25/2013 Disapproved Rich Edgett 1) Fire Dept approval required
2) Service is NOT to be energized until after inspection
3) Install p-ring @ mstr bath floor heat
4) 4AWG SER @ mstr vanity??
5) Recept @ right of sliding glass door in mstr bdrm is over 6"
6) Additional recept may be required @ front grade level
7) Elect. box in hall by laundry (up high) is not wired
8) PEX clearance to canlights
9) GEC to plastic water pipe???
10) Bond Cu sprinkler pipe in unfinished bsmnt
11) Sprinkler pipe incomplete
12) Box in bsmnt unfinished ceiling near I-beam is not wired
NOTE: 2 j-boxes in cabinet @ left of Range
 
Rough Electric 03/27/2013 Disapproved Rich Edgett 1) Add recepts @ bar tops in bsmnt
2) PEX clearance to canlight in bsmnt shower
NOTE: Speaker prewires in ceiling are NOT boxed
OK to insulate pending Frame approval
 
Rough Energy Compliance 03/26/2013 Approved Kerry Keller  
Rough Frame 03/26/2013 Disapproved Kerry Keller 1-Provide Anchor Bolts with 12'' of Bottom Plate Splices
2-Provide Eng. on Stair Frame Change
3-Provide Eng. on Hole Drilled for Elect. Floor Truss
 
Rough Frame 04/01/2013 Cancelled Kerry Keller  
Rough Frame 04/03/2013 Approved Kerry Keller See new Floor Truss in CMS  
Rough Frame Partial 02/20/2013 Approved Kerry Keller ok on porchs and columns  
Rough HVAC 03/26/2013 Approved Kerry Keller  
Rough Plumbing 03/26/2013 Disapproved Kerry Keller RES See Insp. in CMS  
Rough Plumbing 03/28/2013 Disapproved Kerry Keller 1- Items not #3,5 for 3-26-13 inspection  
Rough Plumbing 04/01/2013 Approved Kerry Keller  
Shower Pan 03/19/2013 Approved Kerry Keller  
Special Inspection 03/15/2013 Approved Kerry Keller 1- Okay on per slope of shower pan  
Underground Plumbing 01/30/2013 Approved Kerry Keller  
Weather Resistive Barrier 03/06/2013 Approved Kerry Keller