Building Permit Details
Permit Number:
25-07616
Permit Status:
Completed
Permit Type:
Building
Project Type:
Residential
Description of Work:
RS - Residential
Scope of Work:
Addition
Issued Date:
09/29/2025
CO Issue Date:
Plans Examiner:
Anthony Petty
Job Address:
32 ALBION PL CASTLE ROCK, CO 80108
Building Code:
2021 IRC
Inspections
Contractors
Permit Fees
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Caisson/Footer/WG Letter
10/29/2025
Steel Letter
10/29/2025
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Drip Edge
01/16/2026
Approved
Clayton Rodeback
Print Report
Drywall
12/31/2025
Approved
Clayton Rodeback
Print Report
Electric Service Equipment
12/31/2025
Approved
Jeremy Bock
East exterior panel-ok-fed from garage panel with 125A breaker
Print Report
Electric Trench
12/31/2025
Approved
Jeremy Bock
Extension of existing feeders from garage panel under cinder block wall to exterior panel, 125A breaker in garage panel
Additional set of #2 AWG wires from beneath house to panel, unknown point of origin
Print Report
Exterior Lath
12/03/2025
Approved
Clayton Rodeback
Print Report
Exterior Wall Sheathing
11/18/2025
Approved
Brian Schroder
Print Report
Final Building
03/17/2026
Approved
Clayton Rodeback
Print Report
Final Electric
02/19/2026
Disapproved
Nathan Waldschmidt
1. Kitchen fridge shall be AFCI/GFCI protected.
2. Future island circuit AFCI/GFCI protected.
3. Range circuit/plug shall be GFCI protected.
Print Report
Final Electric
02/20/2026
Approved
Jeremy Bock
Print Report
Final Energy Compliance
03/17/2026
Approved
Clayton Rodeback
Print Report
Insulation Thermal
12/11/2025
Disapproved
Clayton Rodeback
Partial. Ok to cover basement lid at game room.
Print Report
Insulation Thermal
12/29/2025
Approved
Clayton Rodeback
Print Report
Interior Gas Line
12/17/2025
Cancelled
Clayton Rodeback
NOT READY
Print Report
Interior Gas Line
12/22/2025
Approved
Anthony Frank
Print Report
Preliminary Defensible Space
08/11/2025
Approved
Dylan Williams
Print Report
Roof Truss
12/22/2025
Approved
Anthony Frank
Print Report
Rough Electric
12/09/2025
Cancelled
Nathan Waldschmidt
Changed inspection to rough partial.
Print Report
Rough Electric
12/17/2025
Disapproved
Jeremy Bock
1. Exhaust fan missing at master bathroom toilet area
2. Closet lighting in master suite incomplete
3. Smoke/ CO detector wiring missing
4. UFER connection incomplete-located in master bedroom addition SE corner
Print Report
Rough Electric
12/22/2025
Disapproved
Nathan Waldschmidt
1. Smoke/ CO detector wiring still missing.
2. UFER connection incomplete-located in master bedroom addition SE corner. 250.50. (Ground rods installed)
Notes:
3. Chandelier not permitted in master closet. 410.16(C) (ceiling fan rated box installed)
4. Chandelier not permitted above bathtub. 410.10(D) (ceiling fan rated box installed)
Print Report
Rough Electric
12/29/2025
Approved
Jeremy Bock
Fan rated boxes removed from closets, hard wired smoke/ CO detectors installed in bedroom & hallway
Print Report
Rough Electric Partial
12/09/2025
Approved
Nathan Waldschmidt
Basement game room partial rough.
(6) new 2” can lights and new switch fed from upstairs arc fault circuit.
Okay to cover.
Print Report
Rough Energy Compliance
12/22/2025
Approved
Anthony Frank
Print Report
Rough Frame
12/17/2025
Cancelled
Clayton Rodeback
NOT READY
Print Report
Rough Frame
12/22/2025
Approved
Anthony Frank
Print Report
Shower Pan
01/06/2026
Disapproved
Dusty Welz
No water in pan. Minimum of 2” above drain required for test.
Print Report
Shower Pan
01/07/2026
Approved
Clayton Rodeback
Print Report
Slab Electrical
01/27/2026
Approved
Nathan Waldschmidt
Master bath floor heat. 3X3 and 3X4 pattern.
Okay to cover.
Print Report
Special Inspection
12/05/2025
Cancelled
Clayton Rodeback
I generated a structural floor inspection.
Print Report
Structural Floor
12/05/2025
Approved
Clayton Rodeback
Inspection for floor over basement game room.
Need rough electric and insulation inspection.
Print Report
Weather Resistive Barrier
12/03/2025
Approved
Clayton Rodeback
Print Report