Building Permit Details
Permit Number: 25-07616
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Residential
Scope of Work: Addition
Issued Date: 09/29/2025
CO Issue Date:
Plans Examiner: Anthony Petty
Job Address: 32 ALBION PL CASTLE ROCK, CO 80108
Building Code: 2021 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 10/29/2025
Steel Letter 10/29/2025
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drip Edge 01/16/2026 Approved Clayton Rodeback  
Drywall 12/31/2025 Approved Clayton Rodeback  
Electric Service Equipment 12/31/2025 Approved Jeremy Bock East exterior panel-ok-fed from garage panel with 125A breaker  
Electric Trench 12/31/2025 Approved Jeremy Bock Extension of existing feeders from garage panel under cinder block wall to exterior panel, 125A breaker in garage panel
Additional set of #2 AWG wires from beneath house to panel, unknown point of origin
 
Exterior Lath 12/03/2025 Approved Clayton Rodeback  
Exterior Wall Sheathing 11/18/2025 Approved Brian Schroder  
Final Building 03/17/2026 Approved Clayton Rodeback  
Final Electric 02/19/2026 Disapproved Nathan Waldschmidt 1. Kitchen fridge shall be AFCI/GFCI protected.
2. Future island circuit AFCI/GFCI protected.
3. Range circuit/plug shall be GFCI protected.
 
Final Electric 02/20/2026 Approved Jeremy Bock  
Final Energy Compliance 03/17/2026 Approved Clayton Rodeback  
Insulation Thermal 12/11/2025 Disapproved Clayton Rodeback Partial. Ok to cover basement lid at game room.  
Insulation Thermal 12/29/2025 Approved Clayton Rodeback  
Interior Gas Line 12/17/2025 Cancelled Clayton Rodeback NOT READY  
Interior Gas Line 12/22/2025 Approved Anthony Frank  
Preliminary Defensible Space 08/11/2025 Approved Dylan Williams
Roof Truss 12/22/2025 Approved Anthony Frank  
Rough Electric 12/09/2025 Cancelled Nathan Waldschmidt Changed inspection to rough partial.  
Rough Electric 12/17/2025 Disapproved Jeremy Bock 1. Exhaust fan missing at master bathroom toilet area
2. Closet lighting in master suite incomplete
3. Smoke/ CO detector wiring missing
4. UFER connection incomplete-located in master bedroom addition SE corner
 
Rough Electric 12/22/2025 Disapproved Nathan Waldschmidt 1. Smoke/ CO detector wiring still missing.
2. UFER connection incomplete-located in master bedroom addition SE corner. 250.50. (Ground rods installed)
Notes:
3. Chandelier not permitted in master closet. 410.16(C) (ceiling fan rated box installed)
4. Chandelier not permitted above bathtub. 410.10(D) (ceiling fan rated box installed)
 
Rough Electric 12/29/2025 Approved Jeremy Bock Fan rated boxes removed from closets, hard wired smoke/ CO detectors installed in bedroom & hallway  
Rough Electric Partial 12/09/2025 Approved Nathan Waldschmidt Basement game room partial rough.
(6) new 2” can lights and new switch fed from upstairs arc fault circuit.
Okay to cover.
 
Rough Energy Compliance 12/22/2025 Approved Anthony Frank  
Rough Frame 12/17/2025 Cancelled Clayton Rodeback NOT READY  
Rough Frame 12/22/2025 Approved Anthony Frank  
Shower Pan 01/06/2026 Disapproved Dusty Welz No water in pan. Minimum of 2” above drain required for test.  
Shower Pan 01/07/2026 Approved Clayton Rodeback  
Slab Electrical 01/27/2026 Approved Nathan Waldschmidt Master bath floor heat. 3X3 and 3X4 pattern.
Okay to cover.
 
Special Inspection 12/05/2025 Cancelled Clayton Rodeback I generated a structural floor inspection.  
Structural Floor 12/05/2025 Approved Clayton Rodeback Inspection for floor over basement game room.
Need rough electric and insulation inspection.
 
Weather Resistive Barrier 12/03/2025 Approved Clayton Rodeback