Building Permit Details
Permit Number:
23-02343
Permit Status:
Completed
Permit Type:
Building
Project Type:
Residential
Description of Work:
RS - Residential
Scope of Work:
Alteration
Issued Date:
05/02/2023
CO Issue Date:
Plans Examiner:
Anthony Petty
Job Address:
10905 S EAST CHERRY CREEK RD ELBERT, CO 80106
Building Code:
2018 IRC
Inspections
Contractors
Permit Fees
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Final Building
06/07/2023
Approved
Clayton Rodeback
Print Report
Final Electric
06/07/2023
Disapproved
Justin Lett
1. TR receps required at island per 406.12 2. GFCI protection required at center recep of island 3. All receps in island require AFCI protection per 210.12 4. Receptacles that serve counter cannot be under overhang greater than 6” 5. Provide crawler access to check jboxes 6. Label all circuits effected by island change at panels 7. Micro recep requires AFCI/GFCI-210.12/210.8. 8. Grommet at DW cord—see notes that were left at rough electric
Note-smokes/CO ok.
Print Report
Final Electric
07/06/2023
Disapproved
Justin Lett
Correction not completed from previous inspection—3. All receps in island require AFCI protection per 210.12-DW & Disposal circuits still require AFCI protection per 210.12/406.4(D)
Print Report
Final Electric
07/12/2023
Disapproved
Justin Lett
No access—DC employees are not allowed to enter occupied residence without adult present.
Print Report
Final Electric
07/14/2023
Approved
Justin Lett
Note-dual function breakers installed.
Print Report
Interior Gas Line
05/05/2023
Approved
Rick Chadwick
Print Report
Rough Electric
05/04/2023
Approved
Justin Lett
Island only modification. Exterior walls left as is with new devices only.
1. Need 3 receps to cover island counter square footage requirement 2. Add recep to cover wall space of island per 210.52-can be fed from island recep circuit as long as that circuit does not have more than 4 receps per DC amendment to NEC-will verify at final
Notes for final-TR recep at micro, AFCI/GFCI protection per 210.12/210.8/406.4, DW cord need grommet
Note-smoke alarms required in each bedroom, adjacent to each bedroom, every level. All require commercial power, battery back up, fully interconnected
Print Report
Rough Frame
05/05/2023
Approved
Rick Chadwick
Print Report
Rough HVAC
06/07/2023
Approved
Clayton Rodeback
Print Report