Mechanical Permit Details
Permit Number: 23-00089
Permit Status: Completed
Permit Type: Mechanical
Type of Work: Furnace/AC Combo
Issued Date: 01/04/2023
Job Address: 9619 HUGGINS CT PARKER, CO 80134
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Air Conditioner 02/06/2023 Approved Justin Lett  
Final Electric 02/06/2023 Disapproved Justin Lett 1. Connector required at end of FMC in ceiling that contains NM cable 2. Max OCPD for A/C 40A per nameplate-currently 50A installed  
Final Electric 04/03/2023 Approved Justin Lett  
Final HVAC 02/06/2023 Disapproved Justin Lett 1. 1” clearance required to combustible material from B-vent 2. Provide calc on combustion air into confined space 3. CO alarm outside upper bedrooms  
Final HVAC 04/03/2023 Approved Justin Lett Trim left side to gain full 1” of clearance to B-Vent. Owner on-site and is making correction. Correct and proceed.

Combustion air ok