Building Permit Details
Permit Number: 22-02283
Permit Status: Voided
Permit Type: Building
Project Type: Residential
Description of Work: RS - Residential
Scope of Work: Alteration
Issued Date: 03/25/2022
CO Issue Date:
Plans Examiner: Anthony Petty
Job Address: 10632 STAR THISTLE CT HIGHLANDS RANCH, CO 80126
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 07/15/2022
Steel Letter 07/15/2022
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Final Building 07/25/2022 Cancelled UnassignedBldg Cancelled by Web user.  
Final Building 07/28/2022 Disapproved Chris Fuller The engineers letters provided to me for this inspection is for the foundation and steel work only. But I do have an issue with the way the egress window is constructed. It does not match the approved plans and the framing surrounding the window is not done properly.
The plans must show more detail of the egress cut out i.e. lentil, header and trimmers details, fastener details, etc.