Toggle navigation
Building Division Online Services
Department of Public Works Engineering, Building Division
Apply for Permits
Inspections
Schedule Inspections
Cancel Inspections
Searches
Search Contractors
Search Permits
Search Address Jurisdiction
Sign-In
My Profile
Sign Out
Building Permit Details
Permit Number:
22-02225
Permit Status:
Completed
Permit Type:
Building
Project Type:
Residential
Description of Work:
RS - Residential
Scope of Work:
Alteration
Issued Date:
03/02/2022
CO Issue Date:
Plans Examiner:
Anthony Petty
Job Address:
6754 LIONSHEAD PKWY LITTLETON, CO 80124
Building Code:
2018 IRC
Inspections
Contractors
Permit Fees
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Drywall
04/04/2022
Approved
Clayton Rodeback
Print Report
Final Building
10/20/2023
Approved
Dusty Welz
Kitchen , laundry and master bathroom final inspection approved. Pending electrical final inspection.
Print Report
Final Electric
10/23/2023
Disapproved
Henry VanSchaack
1) washer recep requires afci protection per 406.4(D) and 210.12
2) island and kitchen countertop receps require afci protection in addition to GFCI protection per 210.12
3) kitchen lights require afci protection per 210.12
Print Report
Final Electric
10/25/2023
Approved
Henry VanSchaack
Print Report
Interior Gas Line
03/30/2022
Disapproved
Anthony Frank
1. Provide supporting for 1 inch CSST in the dining room .
Print Report
Interior Gas Line
03/31/2022
Approved
Anthony Frank
This is for the gas line to the new range.
Print Report
Rough Electric
03/30/2022
Disapproved
Henry VanSchaack
1) in-line splice device not permitted for extension of homerun to kitchen fan per 334.40
2) master bath incomplete
3) add laundry onto permit
** minimum 3 receps required for island, will check at final **
Print Report
Rough Electric
03/31/2022
Disapproved
Henry VanSchaack
Master bath incomplete
** kitchen and laundry approved **
Print Report
Rough Electric
08/16/2022
Approved
Henry VanSchaack
Master bath
** 3 lights added to existing circuit, unable to verify maximum 10 openings per 15a circuit, will check at final **
Print Report
Rough Frame
03/30/2022
Disapproved
Anthony Frank
1. Have Word docs and plans on job site please.
Print Report
Rough Frame
03/31/2022
Approved
Anthony Frank
1. This is inclusive of the laundry and kitchen.
Print Report
Rough Frame
08/16/2022
Approved
Chris Fuller
Did rough for bath and kit
Print Report
Rough HVAC
03/30/2022
Disapproved
Anthony Frank
1. Seal all snaplock fittings and exhaust and make up there with 181 sealant.
Print Report
Rough Plumbing
03/30/2022
Disapproved
Anthony Frank
1. Install Boca plates on laundry tub waste and drain system.
2. Secure packs water piping in the crawlspace.
Print Report