Building Permit Details
Permit Number: 21-06510
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Basement
Scope of Work: Alteration
Issued Date: 06/30/2021
CO Issue Date:
Plans Examiner: Stuart Foster
Job Address: 5394 SEDONA DR PARKER, CO 80134
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 07/16/2021 Approved Rick Chadwick  
Final Building 08/06/2021 Disapproved Rick Chadwick CO detector 15’ from bedroom  
Final Building 02/25/2022 Approved Clayton Rodeback  
Final Electric 08/06/2021 Disapproved Henry VanSchaack Twin breaker installed to make room for AFCI is not permitted in this breaker space and is not making good electrical contact, must be moved to a correct bus space or panel may need to be replaced  
Final Electric 02/24/2022 Approved Thomas Buzo  
Fireblocking 07/13/2021 Approved Richard Miller  
Interior Gas Line 07/13/2021 Approved Richard Miller  
Rough Electric 07/13/2021 Approved Thomas Buzo One bedroom rough ok.
Check branch circuits home runs at basement sub panel at final.
 
Rough Frame 07/13/2021 Approved Richard Miller