Building Permit Details
Permit Number: 21-02361
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Stock
Scope of Work: New
Issued Date: 06/03/2021
CO Issue Date: 11/29/2021
Plans Examiner: Anthony Petty
Job Address: 8099 MOUNT OURAY RD LITTLETON, CO 80125
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 09/29/2021
Steel Letter 09/29/2021
Survey 09/29/2021
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Construction Meter 08/20/2021 Disapproved Damon Montroy 1. Panel door not connected to panel
2. Fill unused breaker slots
 
Construction Meter 08/25/2021 Approved Damon Montroy Xcel 08/26/2021
Drywall 10/15/2021 Approved Duke Thompson  
Electric Service Equipment 10/28/2021 Disapproved Damon Montroy Laterals not landed  
Electric Service Equipment 10/29/2021 Approved Jeremy Bock Xcel 10/29/2021
Exterior Wall Sheathing 09/01/2021 Cancelled Fredrick Mooney Brian cancelled  
Exterior Wall Sheathing 09/03/2021 Approved Duke Thompson  
Final Building 11/19/2021 Cancelled Robert Stratton Not ready  
Final Building 11/22/2021 Disapproved Robert Stratton 1. Rear deck ledger missing ledger locks & L90 at left end joist
2. Complete range hood exhaust duct
3. Shim water heater from rocking
4. Properly install AAV for floor drain
5. Seal bottom of basement slider
6. Seal hole in insulation at AC line at back walkout wall & rear sump & hose bib supply
 
Final Building 11/23/2021 Approved Robert Stratton  
Final Electric 11/19/2021 Disapproved Damon Montroy 1. Outlets in garage and at front grade have an open neutral
2. NM exposed at AC disconnect.
3. Counter outlets on with fridge - add to description on panel schedule. Add location/description of other counter outlets at panel schedule.
 
Final Electric 11/22/2021 Approved Jeremy Bock  
Final Energy Compliance 11/19/2021 Cancelled Robert Stratton Not ready  
Final Energy Compliance 11/22/2021 Approved Robert Stratton  
Final HVAC 11/19/2021 Cancelled Robert Stratton Not ready  
Final HVAC 11/22/2021 Approved Robert Stratton  
Final Plumbing 11/19/2021 Cancelled Robert Stratton Not ready  
Final Plumbing 11/22/2021 Approved Robert Stratton  
Fireblocking 09/13/2021 Approved Clayton Rodeback  
Insulation Thermal 10/07/2021 Approved Carlo Turchiano  
Interior Gas Line 10/05/2021 Approved Robert Stratton 10lbs Xcel 10/06/2021
Moisture Barrier 10/12/2021 Disapproved Duke Thompson 1. Finish flashing top of moisture barrier north side front southside back corners
2. Caulk and seal around handrail at front of house
 
Moisture Barrier 10/19/2021 Approved Carlo Turchiano  
Roof Truss 09/27/2021 Disapproved Duke Thompson Need engineers letter for broken truss B2 at above back wall of garage  
Roof Truss 10/05/2021 Approved Robert Stratton  
Roof Truss 10/05/2021 Cancelled Fredrick Mooney Complete  
Rough Electric 10/05/2021 Approved Damon Montroy 1. Nail plate required in garage at south wall and SE corner.
2. Install construction receptacle.
Correct and proceed - will check at service inspection.
 
Rough Energy Compliance 10/05/2021 Approved Robert Stratton  
Rough Frame 10/05/2021 Approved Robert Stratton  
Underground Plumbing 08/10/2021 Disapproved Duke Thompson 1. Install all solvent joints using purple primer
2. 3003.9.2
3. Fix and recall
 
Underground Plumbing 08/11/2021 Approved Chris Fuller  
Weather Resistive Barrier 09/13/2021 Approved Clayton Rodeback