Building Permit Details
Permit Number: 20-08037
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Basement
Scope of Work: Alteration
Issued Date: 08/26/2020
CO Issue Date:
Plans Examiner: Stuart Foster
Job Address: 11069 MEADOWVALE CIR HIGHLANDS RANCH, CO 80130
Building Code: 2018 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 09/23/2020 Approved Carlo Turchiano Check mech room insulation at final
Check photos of drywall in bedroom closet
 
Final Building 11/10/2020 Disapproved Chris Fuller Vapor barrier for insulation in mechanical room, ceiling too  
Final Building 11/12/2020 Approved Chris Fuller Put plastic over ceiling insulation of mechanical room  
Final Electric 11/10/2020 Disapproved Matt Mazzara 1)bath recep req GFCI protected
2)rec rm wall recep within 6’ of bar sink req GFCI protected 210.8
3)Siemens breaker not listed for use in GE panel (bsmt sub)
4)bond CSST #6cu, main service or electrode to accessible hard pipe upstream
 
Final Electric 11/16/2020 Approved Matt Mazzara  
Fireblocking 09/16/2020 Approved Chris Fuller  
Interior Gas Line 09/16/2020 Approved Chris Fuller No changes to gas  
Rough Electric 09/16/2020 Approved Matt Mazzara Bond CSST at accessible hard pipe upstream #6cu
Check at final
 
Rough Frame 09/16/2020 Approved Chris Fuller Insulate mechanical room walls ceiling ductwork pipes by final
Egress ladder by final
Rotate water heater for 30 inch clearance in front by final.
 
Underground Plumbing 09/16/2020 Approved Chris Fuller