Building Permit Details
Permit Number:
20-02874
Permit Status:
Completed
Permit Type:
Building
Project Type:
Commercial
Description of Work:
CM - Tenant Improvement
Scope of Work:
Alteration
Issued Date:
08/17/2020
CC Issue Date:
03/29/2021
Plans Examiner:
Stuart Foster, Wayne Elmore
Job Address:
3380 E COUNTY LINE RD HIGHLANDS RANCH, CO 80126
Building Code:
2018 IBC
Inspections
Contractors
Permit Fees
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Caisson/Footer/WG Letter
10/21/2020
Steel Letter
10/21/2020
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Drywall
11/02/2020
Approved
Gary Hartmann
Print Report
Final Building
02/19/2021
Disapproved
Gary Hartmann
Need fire sign off
Print Report
Final Electric
12/31/2020
Approved
Rick Sugar
Print Report
Final Frame
03/11/2021
Approved
Gary Hartmann
Print Report
Final HVAC
12/31/2020
Approved
Gary Hartmann
Print Report
Final Plumbing
12/31/2020
Disapproved
Gary Hartmann
no access to dog wash
Print Report
Final Plumbing
02/19/2021
Approved
Gary Hartmann
Print Report
Rough Electric
10/23/2020
Disapproved
Henry VanSchaack
1) fill unused ko in SE recep in luxor room; 2) nail plate required and secure mc at top plat above switch and recep on south wall of luxor room; 3) secure mc within 12” and 1-1/4” from face of framing on east wall of dog wash; 4) remove abandoned low-volt as far as possible per 725.25 in dog wash
Print Report
Rough Electric
10/26/2020
Approved
Henry VanSchaack
Permit card not on site
Print Report
Rough Frame
10/26/2020
Approved
Gary Hartmann
Print Report
Rough HVAC
10/23/2020
Approved
Gary Hartmann
Print Report
Rough Plumbing
10/23/2020
Approved
Gary Hartmann
Print Report