Building Permit Details
Permit Number:
19-13073
Permit Status:
Voided
Permit Type:
Building
Project Type:
Residential
Description of Work:
RS - Basement
Scope of Work:
Alteration
Issued Date:
11/12/2019
CO Issue Date:
Plans Examiner:
Dave Ransom
Job Address:
11200 SWEET CICELY LN PARKER, CO 80134
Building Code:
2012 IRC
Inspections
Contractors
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Drywall
01/17/2020
Approved
Robert Stratton
Print Report
Final Electric
07/14/2020
Disapproved
Henry VanSchaack
1) disposal switch inverted; 2) spark rings required for all receps in bar tile; 3) recep left of mechanical room loose; 4) listed handle tie required for 2 ckts on same yoke
Print Report
Final Electric
01/12/2021
Approved
Jeremy Bock
Print Report
Interior Gas Line
01/06/2020
Disapproved
Clayton Rodeback
Lost test
Print Report
Interior Gas Line
01/08/2020
Approved
Robert Stratton
10lb at FP
Print Report
Rough Electric
01/06/2020
Disapproved
Henry VanSchaack
1) fireplace incomplete; 2) max 4 cables per stack-it bundled over 24"; 3) max 2 cables per 1/2" connector in sub-panel; 4) max 10 openings per 15a ckt, lighting exceeds; 5) completely remove bond screw from sub-panel
Print Report
Rough Electric
01/08/2020
Approved
Henry VanSchaack
Print Report
Rough Frame
01/06/2020
Disapproved
Clayton Rodeback
Gas line loss test out fireplace.
Stiff back at flat 2x4s in exercise room.
Fire block around fireplace chase to the bottom of first floor OSB
Print Report
Rough Frame
01/08/2020
Approved
Robert Stratton
Print Report
Shower Pan
02/07/2020
Approved
Clayton Rodeback
Print Report