Building Permit Details
Permit Number: 19-13073
Permit Status: Voided
Permit Type: Building
Project Type: Residential
Description of Work: RS - Basement
Scope of Work: Alteration
Issued Date: 11/12/2019
CO Issue Date:
Plans Examiner: Dave Ransom
Job Address: 11200 SWEET CICELY LN PARKER, CO 80134
Building Code: 2012 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Drywall 01/17/2020 Approved Robert Stratton  
Final Electric 07/14/2020 Disapproved Henry VanSchaack 1) disposal switch inverted; 2) spark rings required for all receps in bar tile; 3) recep left of mechanical room loose; 4) listed handle tie required for 2 ckts on same yoke  
Final Electric 01/12/2021 Approved Jeremy Bock  
Interior Gas Line 01/06/2020 Disapproved Clayton Rodeback Lost test  
Interior Gas Line 01/08/2020 Approved Robert Stratton 10lb at FP  
Rough Electric 01/06/2020 Disapproved Henry VanSchaack 1) fireplace incomplete; 2) max 4 cables per stack-it bundled over 24"; 3) max 2 cables per 1/2" connector in sub-panel; 4) max 10 openings per 15a ckt, lighting exceeds; 5) completely remove bond screw from sub-panel  
Rough Electric 01/08/2020 Approved Henry VanSchaack  
Rough Frame 01/06/2020 Disapproved Clayton Rodeback Gas line loss test out fireplace.
Stiff back at flat 2x4s in exercise room.
Fire block around fireplace chase to the bottom of first floor OSB
 
Rough Frame 01/08/2020 Approved Robert Stratton  
Shower Pan 02/07/2020 Approved Clayton Rodeback