Toggle navigation
Building Division Online Services
Department of Public Works Engineering, Building Division
Apply for Permits
Inspections
Schedule Inspections
Cancel Inspections
Searches
Search Contractors
Search Permits
Search Address Jurisdiction
Sign-In
My Profile
Sign Out
Building Permit Details
Permit Number:
19-04695
Permit Status:
Completed
Permit Type:
Building
Project Type:
Residential
Description of Work:
RS - Residential
Scope of Work:
Alteration
Issued Date:
06/05/2019
CO Issue Date:
Plans Examiner:
Anthony Petty
Job Address:
3741 SERENADE RD CASTLE ROCK, CO 80104
Building Code:
2012 IRC
Inspections
Contractors
Permit Fees
Property Details
Structure Details
Documents
JavaScript and Session Cookies must be enabled for this Site.
Scheduled Inspections
Name
Date Scheduled
Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters
Received Date
Inspection History
Name
Date Occurred
Result
Inspector Name
Inspection Comments
Meter Release
Inspection Report
Drywall
09/05/2019
Approved
Kerry Keller
Print Report
Final Building
11/22/2019
Disapproved
Kerry Keller
1) Need to high loop your dish washer drain line
2) Cannot mix ABS to PVC at kitchen drains
3) Need AAV at kitchen sink and veg. sink
4) Complete fire rock and tape garage side
5) Adjust fire door closer to self close and latch
6) Complete weather strip and threshold fire door
Print Report
Final Building
12/03/2019
Approved
Kerry Keller
Print Report
Final Electric
11/22/2019
Disapproved
Justin Lett
See scanned ticket
Print Report
Final Electric
12/03/2019
Approved
Justin Lett
Correct lockout installation, label breakers more specifically, change GFCI right of fridge to TR-correct and proceed, EC on site making corrections
Print Report
Insulation Thermal
09/04/2019
Approved
Kerry Keller
Print Report
Interior Gas Line
08/30/2019
Approved
Clayton Rodeback
Print Report
Rough Electric
08/22/2019
Disapproved
Justin Lett
1. Lights not permitted on SABC in nook 2. Correct 2-4 rule at nook counter
Print Report
Rough Electric
08/26/2019
Approved
Justin Lett
Will need jbox at corner cabinet. Splice kit only acceptable for repairs, not wire extensions.
Print Report
Rough Frame
08/30/2019
Disapproved
Clayton Rodeback
Need eng. letter for ledger bearing at garage fl