Building Permit Details
Permit Number: 14-04453
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Master Plan
Scope of Work: New
Issued Date: 07/18/2014
CO Issue Date: 11/21/2014
Plans Examiner: Angie Velasquez, Anthony Petty, Bridget Rassbach, Daniel Davis, Dave Ransom, Greg Lillmars, Leonard Lucero, Martha Mahr, Patricia Roach, Rose Dederick
Job Address: 5049 MCCLURE LN CASTLE ROCK, CO 80108
Building Code: 2012 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 08/25/2014
Steel Letter 08/20/2014
Survey 08/20/2014
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Construction Meter 07/25/2014 Approved Rich Edgett IREA 07/28/2014
Drywall 10/10/2014 Disapproved Rick Chadwick NOT READY  
Drywall 10/13/2014 Approved Brian Brown  
Electric Service Equipment 09/24/2014 Disapproved Rich Edgett See Rough  
Electric Service Equipment 09/26/2014 Approved Rich Edgett IREA 09/29/2014
Exterior Lath 10/17/2014 Approved Rick Chadwick  
Exterior Underground Gas Line 11/06/2014 Cancelled Kerry Keller  
Exterior Wall Sheathing 08/29/2014 Approved Rick Chadwick  
Exterior Wall Sheathing 08/29/2014 Cancelled Kerry Keller  
Final Building 11/17/2014 Disapproved Clayton Rodeback Complete exterior finish.
Paint exterior pvc.
Secure water heater vent pipes per manufacturer's specs.
 
Final Building 11/19/2014 Approved Clayton Rodeback  
Final Electric 11/17/2014 Disapproved Rich Edgett 1) Laundry counter recepts loose
2) Mstr closet lisght clearance
3) Mstr bdrm & fam rm recepts inop
4) Plate screws stripped at kit GFCI (2nd to left of sink)
5) Install breaker lock for double oven
6) Front porch lights inop
Inspection Stopped (1st flr ONLY)
 
Final Electric 11/18/2014 Disapproved Rich Edgett 1) Add recept below switch in bsmnt bdrm
2) Recepts in gunroom not GFCI
3) Redundant GFCIs in mech room
4) Front grade level recept is loose
5) Rear grade level recept won't reset
 
Final Electric 11/19/2014 Approved Rich Edgett  
Final Energy Compliance 11/17/2014 Approved Clayton Rodeback  
Final Grade 11/21/2014 Approved UnassignedDESC Securities posted
Final HVAC 11/17/2014 Approved Clayton Rodeback  
Final Plumbing 11/17/2014 Approved Clayton Rodeback  
Insulation Thermal 09/29/2014 Approved Kerry Keller  
Interior Gas Line 09/24/2014 Approved Kerry Keller Black Hills Energy 09/25/2014
Midroof 10/30/2014 Disapproved Kerry Keller 1) Tile roof is completed no inspection made.  
Moisture Barrier 11/03/2014 Cancelled Kerry Keller  
Moisture Barrier 11/05/2014 Cancelled Kerry Keller  
Moisture Barrier 11/06/2014 Approved Kerry Keller  
Preliminary DESC 07/18/2014 Cancelled UnassignedDESC
Preliminary Defensible Space 06/23/2014 Approved Jill Welle
Roof Truss 08/28/2014 Approved Kerry Keller  
Roof Truss 08/29/2014 Disapproved Rick Chadwick SEE TICKET  
Roof Truss 09/24/2014 Approved Kerry Keller  
Rough Electric 09/24/2014 Disapproved Rich Edgett Scanned Ticket  
Rough Electric 09/26/2014 Disapproved Rich Edgett 1) Sprinkler bond must be 4AWG  
Rough Electric 09/29/2014 Approved Rich Edgett  
Rough Energy Compliance 09/24/2014 Approved Kerry Keller  
Rough Frame 09/24/2014 Disapproved Kerry Keller res see file for corrections  
Rough Frame 09/26/2014 Approved Kerry Keller  
Rough Frame Partial 09/17/2014 Cancelled Kerry Keller  
Rough Frame Partial 09/18/2014 Disapproved Kerry Keller 1)Need Engineers letter on the straps useds in place of PB-44 and 66 bases and top caps  
Rough Frame Partial 09/24/2014 Approved Kerry Keller 1) ok on porch and columns  
Shower Pan 10/23/2014 Approved Kerry Keller  
Underground Plumbing 08/05/2014 Approved Rick Chadwick POST INSP CARD  
Weather Resistive Barrier 09/17/2014 Cancelled Kerry Keller  
Weather Resistive Barrier 09/24/2014 Approved Kerry Keller