Building Permit Details
Permit Number: 13-02362
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Stock
Scope of Work: New
Issued Date: 05/21/2013
CO Issue Date: 11/18/2013
Plans Examiner: Angie Velasquez, Daniel Davis, Dave Ransom, Leonard Lucero, Martha Mahr, Matt Archer, Rose Dederick
Job Address: 5044 VERMILLION DR CASTLE ROCK, CO 80108
Building Code: 2012 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 08/19/2013
Steel Letter 07/10/2013
Survey 08/20/2013
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Caisson Deck/Pole Barn 10/30/2013 Disapproved Kerry Keller 1- Caisson have bend poured , Provide eng. letter
2- If rear deck is added and not no approved plans you need to obtain a deck permit for change to approved plans. No plans on site for inspection.
 
Caisson Deck/Pole Barn 11/07/2013 Cancelled Jerry Hammerton wrong permit number See 13-07106  
Construction Meter 06/13/2013 Disapproved Rich Edgett Meter line lugs are broken  
Construction Meter 06/14/2013 Approved Rich Edgett IREA 06/17/2013
Drip Edge 07/18/2013 Approved Kerry Keller  
Drip Edge 07/18/2013 Approved Kerry Keller  
Drywall 09/03/2013 Disapproved Rick Chadwick NOT READY  
Drywall 09/05/2013 Approved Kerry Keller  
Electric Service Equipment 09/06/2013 Approved Rich Edgett IREA 09/09/2013
Electric Trench 09/05/2013 Approved Rich Edgett 4-wire service feeder
(2) 1" PVC for phone & TV
 
Exterior Lath 09/27/2013 Approved Kerry Keller  
Exterior Underground Gas Line 11/13/2013 Approved Kerry Keller  
Exterior Wall Sheathing 07/09/2013 Disapproved Kerry Keller 1- No permit posted
2-No approved plans for insp.
3- no address posted
 
Exterior Wall Sheathing 07/11/2013 Approved Kerry Keller  
Final Building 11/13/2013 Disapproved Kerry Keller 1-Provide Egress Ladder at BSMT BDRM Well
2-Ex. fan at down draft not working
3-Paint PVC at H20 heater flues and gas line at deck
4- secure gas line at gas range so to have clearance at shut off
 
Final Building 11/14/2013 Approved Rick Chadwick  
Final Electric 11/08/2013 Disapproved Rich Edgett 1) Fire Dept approval required
2) A/C unit incomplete
3) Panel index incomplete
NO INSPECTION
 
Final Electric 11/12/2013 Disapproved Rich Edgett 1) Protect A/C control wire from critters
2) Loose recept @ laundry sink
3) Hall bath ex-fan inop
4) Relamp liv rm cans & minis
5) Mstr bath ex-fan inop
6) Relamp canlight by recroom closet
 
Final Electric 11/13/2013 Approved Rich Edgett  
Final Energy Compliance 11/13/2013 Approved Kerry Keller  
Final Grade 11/15/2013 Disapproved UnassignedBldg Jerry Dortch did inspection with following comments: Need Drainage Certificate and DESC Deactivation Certificate.
Final Grade 11/18/2013 Approved UnassignedBldg Jerry Dortch has completed the inspection.
Final HVAC 11/13/2013 Approved Kerry Keller  
Final Plumbing 11/13/2013 Approved Kerry Keller see final building  
Fireblocking 08/21/2013 Approved Kerry Keller  
Insulation Thermal 08/27/2013 Approved Clayton Rodeback  
Interior Gas Line 08/21/2013 Disapproved Kerry Keller 1-Maintain 10 psi test only with 30 psi max ga.  
Interior Gas Line 08/23/2013 Approved Kerry Keller Black Hills Energy 08/26/2013
Midroof 07/18/2013 Disapproved Kerry Keller 1- not ready no tile installed  
Midroof 10/22/2013 Approved Clayton Rodeback  
Moisture Barrier 10/11/2013 Approved Clayton Rodeback  
Preliminary DESC 07/18/2013 Cancelled Jerry Dortch
Preliminary Defensible Space 04/17/2013 Approved Jill Welle
Roof Truss 07/11/2013 Approved Kerry Keller  
Rough Electric 08/21/2013 Disapproved Rich Edgett Scanned Ticket  
Rough Electric 08/23/2013 Approved Rich Edgett 1) Seal wire penetrations to RA in bsmnt hallway
Will check @ Final: from utility room
 
Rough Energy Compliance 09/10/2013 Approved Kerry Keller 1- Passed 8/23/2013  
Rough Frame 08/21/2013 Disapproved Kerry Keller 1- No County Approved Plans for Insp.
2- missing air barrier at BSMT tub and call rough energy insp. for insp.
No Structural inspection made Recall
 
Rough Frame 08/23/2013 Approved Kerry Keller  
Rough Frame Partial 07/11/2013 Approved Kerry Keller Ok on porch and columns framing  
Rough HVAC 08/21/2013 Approved Kerry Keller  
Rough Plumbing 08/21/2013 Disapproved Kerry Keller 1- Plumbing test ok DWV and H2o
2-Max support on Horiz. H2o piping is 32'' max
2- Plex piping need tobe 12'' away from top of can light or insulate it ck BSMT Stair light
 
Rough Plumbing 08/23/2013 Approved Kerry Keller  
Rough Plumbing 08/26/2013 Cancelled Kerry Keller  
Shower Pan 09/30/2013 Disapproved Kerry Keller 1- not installed recall  
Shower Pan 10/02/2013 Approved Jerry Hammerton  
Ufer Ground Electrode 09/26/2013 Cancelled Rich Edgett NA  
Underground Plumbing 06/05/2013 Approved Kerry Keller  
Weather Resistive Barrier 07/15/2013 Approved Kerry Keller