Building Permit Details
Permit Number: 12-18307
Permit Status: Completed
Permit Type: Building
Project Type: Residential
Description of Work: RS - Duplex
Scope of Work: New
Issued Date: 02/14/2013
CO Issue Date: 09/11/2013
Plans Examiner: Angie Velasquez, Daniel Davis, Dave Ransom, Leonard Lucero, Martha Mahr, Matt Archer, Rose Dederick
Job Address: 4338 CHATEAU RIDGE RD CASTLE ROCK, CO 80108
Building Code: 2006 IRC
Scheduled Inspections
Name Date Scheduled Estimated Time of Inspection
Engineering Letters
Engineering Letters will be listed below if they are required for your project. They must be submitted before scheduling above ground inspections.
Required Engineering Letters Received Date
Caisson/Footer/WG Letter 06/20/2013
Steel Letter 06/21/2013
Survey 06/24/2013
Inspection History
Name Date Occurred Result Inspector Name Inspection Comments Meter Release Inspection Report
Construction Meter 04/08/2013 Disapproved Rich Edgett 1) Drive ground rod (min. 5' from utility equip)  
Construction Meter 04/09/2013 Disapproved Rich Edgett 1) Drive ground rod (min. 5' from utility equip)
2nd time
 
Construction Meter 04/12/2013 Approved Rich Edgett IREA 04/15/2013
Drip Edge 06/13/2013 Approved Rick Chadwick GUTTERS ALREADY INSTALLED COULD NOT VERIFY CODE COMPLIANCE  
Drywall 07/02/2013 Cancelled Kerry Keller  
Drywall 07/05/2013 Disapproved Kerry Keller 1- Still in installing not ready
ck insulation bsmt fire place
 
Drywall 07/09/2013 Approved Kerry Keller  
Electric Trench 07/03/2013 Disapproved Rich Edgett 1) EGC required in trench with feeders
2) Install plastic bushing @ end of PVC underground
 
Electric Trench 07/09/2013 Approved Rich Edgett  
Exterior Lath 07/12/2013 Cancelled Kerry Keller Cancelled by office  
Exterior Lath 07/15/2013 Approved Kerry Keller  
Exterior Wall Sheathing 05/20/2013 Disapproved Rick Chadwick POST ADDRESS POST INSP CARD  
Exterior Wall Sheathing 05/22/2013 Approved Kerry Keller  
Final Building 08/16/2013 Approved Kerry Keller  
Final Building 08/20/2013 Cancelled Kerry Keller passed 8/16/2013 kk  
Final Electric 08/14/2013 Disapproved Henry VanSchaack 1) Front garage and upper back deck receps not WR; 2)Powder rm and bsmt bath receps dead; 3)Recep on room side of wet bar and tv recep are dead.  
Final Electric 08/15/2013 Approved Henry VanSchaack  
Final Energy Compliance 08/16/2013 Approved Kerry Keller  
Final HVAC 08/14/2013 Cancelled Kerry Keller  
Final HVAC 08/15/2013 Approved Kerry Keller  
Final Plumbing 08/16/2013 Approved Kerry Keller  
Fireblocking 06/26/2013 Approved Kerry Keller  
Firewall 06/17/2013 Approved Kerry Keller  
Insulation Thermal 06/28/2013 Approved Kerry Keller  
Interior Gas Line 06/17/2013 Disapproved Kerry Keller no test not ready  
Interior Gas Line 06/26/2013 Disapproved Kerry Keller 1- need 30psi max gauge with 10psi test . no 100psi gauges  
Interior Gas Line 06/28/2013 Approved Kerry Keller Xcel 08/09/2013
Midroof 06/26/2013 Disapproved Kerry Keller res  
Midroof 06/28/2013 Approved Kerry Keller  
Moisture Barrier 07/24/2013 Disapproved Rick Chadwick NOT READY  
Moisture Barrier 08/01/2013 Disapproved Kerry Keller still in stalling  
Moisture Barrier 08/02/2013 Approved Kerry Keller  
Roof Truss 06/17/2013 Approved Kerry Keller  
Rough Electric 06/26/2013 Approved David Lewis  
Rough Energy Compliance 06/28/2013 Approved Kerry Keller  
Rough Frame 06/26/2013 Disapproved Kerry Keller res see cms  
Rough Frame 06/28/2013 Approved Kerry Keller  
Rough Frame Partial 05/22/2013 Approved Kerry Keller ok on porchs and columns  
Rough HVAC 06/26/2013 Approved Kerry Keller  
Rough Plumbing 06/26/2013 Approved Kerry Keller  
Shower Pan 07/09/2013 Disapproved Kerry Keller 1- No test  
Shower Pan 07/18/2013 Approved Kerry Keller  
Underground Plumbing 04/26/2013 Approved Kerry Keller  
Weather Resistive Barrier 06/04/2013 Approved Kerry Keller